The UK’s Leading Stove, Fire & Fireplace Specialist

0330 088 3156 (local call rate & mobile friendly number)



Gas Fires

Kinder Camber HE Gas Fire

  • Maximum heat output (NG) 3.4kW/84.3% efficient (In accordance with the new EU directive for energy ratings effective from January 2018)
  • Click link to view the (NG) energy label
    Kinder Camber HE NG
  • Efficient Gas fire providing both Radiant & Convected Heat
  • Satin Silver Trim
  • Manual control as standard with optional extra Fully Automatic remote control available at an additional cost
  • Coal or Pebble Fuel Effect
  • Suitable for class 1, 2 prefabricated & precast flues*
  • Glass fronted High Efficiency inset fire
  • Plain Black Fire Back
  • Natural gas only
  • Flame Supervision Device (FSD), that cuts the supply of gas if the flame goes out or becomes unstable
  • Oxygen Depletion Sensor which shuts off the gas supply to the main burner in the unlikely event of a fault
  • Inset depth of 180mm
  • Click here to view the
    Kinder Sales Brochure
  • Click here to view the
    Kinder Camber HE Installation & User Instructions
  • Click here to view the
    Kinder Camber HE Technical Drawing

Delivery Information Delivery

Free Delivery!

estimated delivery
3 working days

Need a brochure for the Kinder Camber HE Gas Fire?
stove brochures
Have you seen this stove cheaper? Email our price comparison team.price compare
Kinder Camber HE Gas Fire

Kinder Camber HE Gas Fire
Product No: SM7280

Bookmark and Share

was £1,199.00
NOW £829.99

QTY

Trims | Kinder Camber HE Gas Fire

Camber Silver
Camber Silver
included


Fuel Effect | Kinder Camber HE Gas Fire

Coal
Coal
included
Pebbles
Pebbles
add £60.00


Energy Type | Kinder Camber HE Gas Fire

Kinder Natural Gas <br>
Kinder Natural Gas

included


Controls | Kinder Camber HE Gas Fire

Camber HE Manual Control  <br>  <br>
Camber HE Manual Control


included
Camber HE Fully  <br>Automatic Remote Control
Camber HE Fully
Automatic Remote Control

add £250.00


Specifications | Kinder Camber HE Gas Fire

External Dimensions
See Table
mm
See Table
mm
See Table
mm

Flue


mm
mm
mm
mm
Output
See Table

Details
See Table



Notes

External Height
External Width
Inset Height
Inset Width
Inset Depth
Heat Output (kW)
Black Magic
610
520
550
375
170
2.7
N/A
Camber
610
520
550
365
170
2.7
N/A
Camber HE
610
520
550
365
180
3.4
84%
Camber Plus
610
520
548
365
170
4.2
68%
Dakota
620
470
570
400
125
2.7
80%
Kalahari
598
497
550
365
170
2.7
N/A
Kalahari HE
598
497
550
365
180
3.4
84%
Kalahari Plus
600
498
548
365
170
4.2
68%
Nevada
598
497
550
325
100
3.1
53%
Nevada HE
598
497
550
327
125
2.9
81%
Nevada Plus
600
498
548
324
125
4.0
67%
Oasis
594
495
550
400
250
3.7
60%
Oasis HE
598
497
550
400
230
3.9
86%
Oasis Plus
600
498
548
400
223
4.1
67%
Revolution BF
598
497
551
406
185
3.9
94%
Revolution Arcadia BF
598
497
551
406
185
3.9
94%
Revolution Camber BF
610
520
551
406
185
3.9
94%
Revolution Embrace BF
598
497
551
406
185
3.9
94%
Revolution Signature BF
598
497
551
406
185
3.9
94%
Revolution Ultimo BF
598
497
551
406
185
3.9
94%


NOTE: All measurements are in millimetres (mm). CF is an abbreviation of conventional flue. Please ensure to have a survey carried out by a Gas Safe Register registered gas installer to check and certify the compatibility of your room and intended location with this fire before making any purchase to avoid disappointment. The touchlight top control option will only operate after manually lighting the permanent pilot, the fire is then controlled from two high level switches - On/Off and High/ Low. Mains electricity may be required. Also be aware that due to the fire producing heat the interior of the fire may become marked over time through general wear and tear which is quite normal and to be expected. The inside of the glass may also require cleaning from time to time due to condensation that may form on the inside of the glass. As with all balanced flue gas fires and glass fronted fires generally, the glass may have condensation marks appear on the inside of the glass from time to time which is quite normal and to be expected. Simply remove the glass periodically and clean the glass with a suitable glass cleaner, allow to dry thoroughly and replace accordingly. The flame adjuster feature mentioned in some of the manufacturers instructions for Kinder gas fires only applies to certain Natural Gas (NG) models and excludes all Liquid Propane (LPG) models. The 15 year Guarantee/Warranty offered by BFM Europe Limited on Kinder gas fires covers manufacturing and material defects, including parts and labour (but excludes consumables), providing and subject to an annual service and annual replacement of the oxy-pilot assembly being performed each and every year during the 15 year period, from the date of purchase. Failure to carry out a service annually and or replacement of the oxy-pilot would render the 15 year Guarantee/Warranty null & void and you would only be entitled to a statutory 1 year manufacturers Guarantee/Warranty. NOTE Combustible material should be at kept away from this appliance at all times.

Click here for information on heat resistant materials that can be used with the installation of high output fires including heat resistant plaster, fillers and associated products
Victas Heat Resistant Materials



Terms & Conditions | Delivery & Returns | Brochures | Copyright | Disclaimer | Failed Orders | Privacy Policy

© 1997 - 2024 Stove Megastore - the fire, fireplace & stove specialist    Authorised dealer for Pinnacle - Lumia - Formosa Fires - Beaucrest - Garland

All major credit and debit cards accepted      Gas Safety Register HETAS NICEIC